Silicon Laboratories C8051F340 Bedienungsanleitung Seite 260

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 282
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 259
C8051F340/1/2/3/4/5/6/7
260 Rev. 0.5
When T3SPLIT = ‘1’, the Timer 3 registers (TMR3H and TMR3L) act as two 8-bit counters. Each counter
counts up independently and overflows from 0xFF to 0x00. Each time a capture event is received, the con
-
tents of the Timer 3 registers are latched into the Timer 3 Reload registers (TMR3RLH and TMR3RLL). A
Timer
3 interrupt is generated if enabled.
Figure 21.11. Timer 3 Capture Mode (T3SPLIT = ‘1’)
SYSCLK
TCLK
0
1
TR3
External Clock / 8
SYSCLK / 12
0
1
1
0
TMR3H
TMR3RLH
TCLK
TMR3L
TMR3RLL
To ADC
CKCON
T
3
M
H
T
3
M
L
S
C
A
0
S
C
A
1
T
0
M
T
2
M
H
T
2
M
L
T
1
M
TMR3CN
T
F
3
H
T
F
3
L
T
3
X
C
L
K
T
3
C
S
S
T
R
3
T
F
3
L
E
N
T
3
C
E
T
3
S
P
L
I
T
Capture
Enable
Capture
Interrupt
USB Start-of-Frame (SOF)
Low-Frequency Oscillator
Falling Edge
0
1
T3CSS
Seitenansicht 259
1 2 ... 255 256 257 258 259 260 261 262 263 264 265 ... 281 282

Kommentare zu diesen Handbüchern

Keine Kommentare